Install stove pipe chimney pipe and chimney kits and more discount chimney supply inc.
Wood heater flue kit installation.
To order items below or enquire please contact us with the product description.
It is not made to pass through walls and does not have proper fittings available to construct a full chimney setup.
This through the wall chimney stove vent kit supports up to 40 ft.
In summary in order to satisfy the building regulations if a flue or chimney exits the roof more than 600mm from the ridge of the roof then the horizontal distance from the top of the flue or chimney should be at least 2300mm above the roof or ridge.
This measurement is usually between 8 12 inches though it can vary by brand.
Stove pipe is used to make a final interior connection between the chimney or chimney kit to the appliance.
After that add any height needed above the chimney chase for a storm collar and chimney cap.
Simply measure the distance from the top of the as installed appliance flue collar to the as built height of the chimney chase.
3 m 10 ft.
For the exact rules in your area check with a local wood heat retailer chimney sweep or building inspector.
The goal is for the stove pipe to slide over the stove adaptor and fit on the flue of the stove.
Wood heater flue kits all require stainless steel min 304 guage flues as an active flue but the outer flues can be galvanised or stainless flue if you prefer.
Ukpop6 6 universal kit with perf with windless cowl 580.
Pellet stove vent pipe has a 3 stainless steel interior pipe with an air gap and then a 4 outer pipe of galvanised steel.
The duraplus system from duravent is designed to the duraplus system from duravent is designed to stay cool on the outside provide a hot draft on the inside and boost stove efficiency offering a fire safe design that protects both the chimney and building.
Don t be caught out.
As you can see in the professional pellet stove installation video above pellet stove vent pipe resembles gas stove flue pipe more than a wood stoves chimney.
Flue kit roof installation wildcat flue systems should be at least 1000mm above the top of the opening.
Once you have the measurements for the pipe to fit accurately cut and slide into.
This stipulates that the minimum flue height must be 4 6m above the floor on which the wood heater is located.
Duravent duraplus basic chimney kit vertical installation 4 1 out of 5 stars 23 simpson duravent 6dvl 12 order 810000902 double wall interior black stovepipe connects wood stoves to chimney 016 stainless steel inner wall 018 galvanized outer 12 length 6 inner diameter.
Maximum overall length of straight pipe.
Some heavy lifting will be required with maneuvering a wood stove.
All wood heater installations are regulated by australian standard as nzs2918 and must comply with australian standard as nzs 2918 2001.
Installation rules for flue pipes also called stove pipe smoke pipe chimney connector etc the rules provided here are based on the csa installation code used in canada.
The most common misconception we have found amongst most wood heater retailers is that a 3 6m flue kit is standard and is enough for the heater to comply.
Of duraplus chimney pipe sold separately and features the necessary.